Man page of ipmitool
· Home
· Download
· Manpage
· Mailing List
· Sourceforge
|
NAME
ipmitool - utility for controlling IPMI-enabled devices
SYNOPSIS
ipmitool [-c|-h|-v|-V]
-I open <command>
ipmitool [-c|-h|-v|-V]
-I lan -H <hostname>
[-p <port>]
[-U <username>]
[-A <authtype>]
[-L <privlvl>]
[-a|-E|-P|-f <password>]
[-o <oemtype>]
<command>
ipmitool [-c|-h|-v|-V]
-I lanplus -H <hostname>
[-p <port>]
[-U <username>]
[-L <privlvl>]
[-a|-E|-P|-f <password>]
[-o <oemtype>]
[-C <ciphersuite>]
<command>
DESCRIPTION
This program lets you manage Intelligent Platform Management Interface
(IPMI) functions of either the local system, via a kernel device driver,
or a remote system, using IPMI V1.5 and IPMI v2.0. These functions include
printing FRU information, LAN configuration, sensor readings, and remote
chassis power control.
IPMI management of a local system interface requires a compatible IPMI
kernel driver to be installed and configured. On Linux this driver is
called OpenIPMI and it is included in standard distributions.
On Solaris this driver is called BMC and is inclued in Solaris 10.
Management of a remote station requires the IPMI-over-LAN interface to be
enabled and configured. Depending on the particular requirements of each
system it may be possible to enable the LAN interface using ipmitool over
the system interface.
OPTIONS
- -a
-
Prompt for the remote server password.
- -A <authtype>
-
Specify an authentication type to use during IPMIv1.5 lan
session activation. Supported types are NONE, PASSWORD, MD5, or OEM.
- -c
-
Present output in CSV (comma separated variable) format.
This is not available with all commands.
- -C <ciphersuite>
-
The remote server authentication, integrity, and encryption algorithms
to use for IPMIv2 lanplus connections. See table 22-19 in the
IPMIv2 specification. The default is 3 which specifies RAKP-HMAC-SHA1
authentication, HMAC-SHA1-96 integrity, and AES-CBC-128 encryption algorightms.
- -E
-
The remote server password is specified by the environment
variable IPMI_PASSWORD.
- -f <password_file>
-
Specifies a file containing the remote server password. If this
option is absent, or if password_file is empty, the password
will default to NULL.
- -h
-
Get basic usage help from the command line.
- -H <address>
-
Remote server address, can be IP address or hostname. This
option is required for lan and lanplus interfaces.
- -I <interface>
-
Selects IPMI interface to use. Supported interfaces that are
compiled in are visible in the usage help output.
- -L <privlvl>
-
Force session privilege level. Can be CALLBACK, USER,
OPERATOR, ADMIN. Default is ADMIN.
- -m <local_address>
-
Set the local IPMB address. The default is 0x20 and there
should be no need to change it for normal operation.
- -o <oemtype>
-
Select OEM type to support. This usually involves minor hacks
in place in the code to work around quirks in various BMCs from
various manufacturers. Use -o list to see a list of
current supported OEM types.
- -p <port>
-
Remote server UDP port to connect to. Default is 623.
- -P <password>
-
Remote server password is specified on the command line.
If supported it will be obscured in the process list.
Note! Specifying the password as a command line
option is not recommended.
- -t <target_address>
-
Bridge IPMI requests to the remote target address.
- -U <username>
-
Remote server username, default is NULL user.
- -v
-
Increase verbose output level. This option may be specified
multiple times to increase the level of debug output. If given
three times you will get hexdumps of all incoming and
outgoing packets.
- -V
-
Display version information.
If no password method is specified then ipmitool will prompt the
user for a password. If no password is entered at the prompt,
the remote server password will default to NULL.
SECURITY
There are several security issues be be considered before enabling the
IPMI LAN interface. A remote station has the ability to control a system's power
state as well as being able to gather certain platform information. To reduce
vulnerability it is strongly advised that the IPMI LAN interface only be
enabled in 'trusted' environments where system security is not an issue or
where there is a dedicated secure 'management network'.
Further it is strongly advised that you should not enable IPMI for
remote access without setting a password, and that that password should
not be the same as any other password on that system.
When an IPMI password is changed on a remote machine with the IPMIv1.5
lan interface the new password is sent across the network
as clear text. This could be observed and then used to attack the remote
system. It is thus recommended that IPMI password management only be done
over IPMIv2.0 lanplus interface or the system interface on the
local station.
For IPMI v1.5, the maximum password length is 16 characters.
Passwords longer than 16 characters will be truncated.
For IPMI v2.0, the maximum password length is 20 characters;
longer passwords are truncated.
COMMANDS
- help
-
This can be used to get command-line help on ipmitool
commands. It may also be placed at the end of commands
to get option usage help.
ipmitool help
Commands:
raw Send a RAW IPMI request and print
response
lan Configure LAN Channels
chassis Get chassis status and set power
state
event Send pre-defined events to MC
mc Management Controller status and
global enables
sdr Print Sensor Data Repository
entries and readings
sensor Print detailed sensor information
fru Print built-in FRU and scan SDR
for FRU locators
sel Print System Event Log (SEL)
pef Configure Platform Event Filtering
(PEF)
sol Configure IPMIv2.0 Serial-over-LAN
isol Configure IPMIv1.5 Serial-over-LAN
user Configure Management Controller
users
channel Configure Management Controller
channels
session Print session information
exec Run list of commands from file
set Set runtime variable for shell and
exec
ipmitool chassis help
Chassis Commands: status, power, identify, policy, restart_cause, poh, bootdev
ipmitool chassis power help
chassis power Commands: status, on, off, cycle, reset, diag, soft
- bmc|mc
-
-
- reset <warm|cold>
-
Instructs the BMC to perform a warm or cold reset.
- info
-
Displays information about the BMC hardware, including device
revision, firmware revision, IPMI version supported, manufacturer ID,
and information on additional device support.
- getenables
-
Displays a list of the currently enabled options for the BMC.
- setenables <option>=[on|off]
-
Enables or disables the given option. This command is
only supported over the system interface according to the IPMI
specification. Currently supported values for option include:
-
- recv_msg_intr
-
Receive Message Queue Interrupt
- event_msg_intr
-
Event Message Buffer Full Interrupt
- event_msg
-
Event Message Buffer
- system_event_log
-
System Event Logging
- oem0
-
OEM-Defined option #0
- oem1
-
OEM-Defined option #1
- oem2
-
OEM-Defined option #2
- channel
-
-
- authcap <channel number> <max priv>
-
Displays information about the authentication capabilities of
the selected channel at the specified privilege level.
-
- Possible privilege levels are:
-
1 Callback level
2 User level
3 Operator level
4 Administrator level
5 OEM Proprietary level
- info [channel number]
-
Displays information about the
selected channel. If no channel is given it will
display information about the currently used channel:
-
ipmitool channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
- getaccess <channel number> [userid]
-
Configure the given userid as the default on the given channel number.
When the given channel is subsequently used, the user is identified
implicitly by the given userid.
- setaccess <channel number> <userid>
-
[callin=on|off]
[ipmi=on|off]
[link=on|off]
[privilege=level]
Configure user access information on the given channel for the given userid.
- getciphers <all | supported> <ipmi | sol> [channel]
-
Displays the list of cipher suites supported for the given
application (ipmi or sol) on the given channel.
- chassis
-
-
- status
-
Displays information regarding the high-level
status of the system chassis and main power
subsystem.
- poh
-
This command will return the Power-On Hours counter.
- identify <interval>
-
Control the front panel identify light. Default
is 15. Use 0 to turn off.
- restart_cause
-
Query the chassis for the cause of the last system restart.
- policy
-
Set the chassis power policy in the event power failure.
-
- list
-
Return supported policies.
- always-on
-
Turn on when power is restored.
- previous
-
Returned to previous state when power is restored.
- always-off
-
Stay off after power is restored.
- power
-
Performs a chassis control command to view and
change the power state.
-
- status
-
Show current chassis power status.
- on
-
Power up chassis.
- off
-
Power down chassis into soft off (S4/S5 state).
WARNING: This command does not initiate a clean
shutdown of the operating system prior to powering down the system.
- cycle
-
Provides a power off interval of at least 1 second. No action
should occur if chassis power is in S4/S5 state, but it is
recommended to check power state first and only issue a power
cycle command if the system power is on or in lower sleep
state than S4/S5.
- reset
-
This command will perform a hard reset.
- diag
-
Pulse a diagnostic interrupt (NMI) directly to the processor(s).
- soft
-
Initiate a soft-shutdown of OS via ACPI. This can be done in a
number of ways, commonly by simulating an overtemperture or by
simulating a power button press. It is necessary for there to
be Operating System support for ACPI and some sort of daemon
watching for events for this soft power to work.
- bootdev <device>
-
Request the system to boot from an alternate boot device on next reboot.
-
- Currently supported values for <device> are:
-
- pxe
-
Force PXE boot
- disk
-
Force boot from BIOS default boot device
- safe
-
Force boot from BIOS default boot device, request Safe Mode
- diag
-
Force boot from diagnostic partition
- cdrom
-
Force boot from CD/DVD
- bios
-
Force boot into BIOS setup
- event
-
-
- <predefined event number>
-
Send a pre-defined event to the System Event Log. The following
events are included as a means to test the functionality of the
System Event Log component of the BMC (an entry will be added each
time the event n command is executed).
Currently supported values for n are:
1 Temperature: Upper Critical: Going High
2 Voltage Threshold: Lower Critical: Going Low
3 Memory: Correctable ECC Error Detected
NOTE: These pre-defined events will likely not produce
"accurate" SEL records for a particular system because they will
not be correctly tied to a valid sensor number, but they are
sufficient to verify correct operation of the SEL.
- file <filename>
-
Event log records specified in filename will be added to
the System Event Log.
The format of each line in the file is as follows:
<{EvM Revision} {Sensor Type} {Sensor Num} {Event Dir/Type} {Event Data 0} {Event Data 1} {Event Data 2}>[# COMMENT]
Note: The Event Dir/Type field is encoded with the event direction
as the high bit (bit 7) and the event type as the low 7 bits.
e.g.:
0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower Critical: Going Low
- exec <filename>
-
-
Execute ipmitool commands from filename. Each line is a
complete command. The syntax of the commands are defined by the
COMMANDS section in this manpage. Each line may have an optional
comment at the end of the line, delimited with a `#' symbol.
e.g., a command file with two lines:
sdr list # get a list of sdr records
sel list # get a list of sel records
- fru
-
-
- print
-
This command will read all Field Replaceable Unit (FRU) inventory
data and extract such information as serial number, part number, asset
tags, and short strings describing the chassis, board, or product.
- i2c <i2caddr> <read bytes> [<write data>]
-
This will allow you to execute raw I2C commands with the Master
Write-Read IPMI command.
- isol
-
-
- setup <baud rate>
-
Setup baud rate for IPMI v1.5 Serial-over-LAN.
- lan
-
-
- print <channel>
-
Print the current configuration for the given channel.
- set <channel> <parameter>
-
Set the given parameter on the given channel.
Valid parameters are:
-
- ipaddr <x.x.x.x>
-
Set the IP address for this channel.
- netmask <x.x.x.x>
-
Set the netmask for this channel.
- macaddr <xx:xx:xx:xx:xx:xx>
-
Set the MAC address for this channel.
- defgw ipaddr <x.x.x.x>
-
Set the default gateway IP address.
- defgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the default gateway MAC address.
- bakgw ipaddr <x.x.x.x>
-
Set the backup gateway IP address.
- bakgw macaddr <xx:xx:xx:xx:xx:xx>
-
Set the backup gateway MAC address.
- password <pass>
-
Set the null user password.
- snmp <community string>
-
Set the SNMP community string.
- user
-
Enable user access mode for userid 1 (issue the `user'
command to display information about userids for a given channel).
- access <on|off>
-
Set LAN channel access mode.
- ipsrc <source>
-
Set the IP address source:
none unspecified
static manually configured static IP address
dhcp address obtained by BMC running DHCP
bios address loaded by BIOS or system software
- arp respond <on|off>
-
Set BMC generated ARP responses.
- arp generate <on|off>
-
Set BMC generated gratuitous ARPs.
- arp interval <seconds>
-
Set BMC generated gratuitous ARP interval.
- auth <level,...> <type,...>
-
Set the valid authtypes for a given auth level.
Levels: callback, user, operator, admin
Types: none, md2, md5, password, oem
- cipher_privs <privlist>
-
Correlates cipher suite numbers with the maximum privilege
level that is allowed to use it. In this way, cipher suites can restricted
to users with a given privilege level, so that, for example,
administrators are required to use a stronger cipher suite than
normal users.
The format of privlist is as follows. Each character represents
a privilege level and the character position identifies the cipher suite
number. For example, the first character represents cipher suite 1
(cipher suite 0 is reserved), the second represents cipher suite 2, and
so on. privlist must be 15 characters in length.
Characters used in privlist and their associated privilege levels are:
X Cipher Suite Unused
c CALLBACK
u USER
o OPERATOR
a ADMIN
O OEM
So, to set the maximum privilege for cipher suite 1 to USER and suite 2 to
ADMIN, issue the following command:
ipmitool -I interface lan set channel cipher_privs uaXXXXXXXXXXXXX
- pef
-
-
- info
-
This command will query the BMC and print information about the PEF
supported features.
- status
-
This command prints the current PEF status (the last SEL entry
processed by the BMC, etc).
- policy
-
This command lists the PEF policy table entries. Each policy
entry describes an alert destination. A policy set is a
collection of table entries. PEF alert actions reference policy sets.
- list
-
This command lists the PEF table entries. Each PEF entry
relates a sensor event to an action. When PEF is active,
each platform event causes the BMC to scan this table for
entries matching the event, and possible actions to be taken.
Actions are performed in priority order (higher criticality first).
- raw <netfn> <cmd> [data]
-
This will allow you to execute raw IPMI commands. For
example to query the POH counter with a raw command:
ipmitool -v raw 0x0 0xf
RAW REQ (netfn=0x0 cmd=0xf data_len=0)
RAW RSP (5 bytes)
3c 72 0c 00 00
- sdr
-
-
- info
-
This command will query the BMC for SDR information.
- list [all|full|compact|event|mcloc|fru|generic]
-
This command will read the Sensor Data Records (SDR) and
extract sensor information of a given type, then query each sensor and
print its name, reading, and status.
-
- Valid types are:
-
-
- all
-
All SDR records (Sensor and Locator)
- full
-
Full Sensor Record
- compact
-
Compact Sensor Record
- event
-
Event-Only Sensor Record
- mcloc
-
Management Controller Locator Record
- fru
-
FRU Locator Record
- generic
-
Generic SDR records
- entity <id>[.<instance>]
-
Displays all sensors associated with an entity. Get a list of
valid entity ids on the target system by issuing the `sdr list' command
with the verbose option (`-v'). A list of all entity ids can be found
in the IPMI specifications.
- dump <file>
-
Dumps raw SDR data to a file.
- sel
-
NOTE: SEL entry-times are displayed as `Pre-Init Time-stamp'
if the SEL clock needs to be set.
Ensure that the SEL clock is accurate by invoking the `sel time get'
and `sel time set <time string>' commands.
-
- info
-
This command will query the BMC for information
about the System Event Log (SEL) and its contents.
- clear
-
This command will clear the contents of the SEL.
It cannot be undone so be careful.
- list
-
When this command is invoked without arguments, the entire
contents of the SEL are displayed.
-
- <count>|first <count>
-
Displays the first count (least-recent) entries in the SEL.
If count is zero, all entries are displayed.
- last <count>
-
Displays the last count (most-recent) entries in the SEL.
If count is zero, all entries are displayed.
- delete <number>
-
Delete a single event.
- time
-
-
- get
-
Displays the SEL clock's current time.
- set <time string>
-
Sets the SEL clock. Future SEL entries will use the time
set by this command. <time string> is of the
form "MM/DD/YYYY HH:MM:SS". Note that hours are in 24-hour
form. It is recommended that the SEL be cleared before
setting the time.
- sensor
-
-
- list
-
Lists sensors and thresholds in a wide table format.
- get <id> ... [<id>]
-
Prints information for sensors specified by name.
- thresh <id> <threshold> <setting>
-
This allows you to set a particular sensor threshold
value. The sensor is specified by name.
-
- Valid thresholds are:
-
unr Upper Non-Recoverable
ucr Upper Critical
unc Upper Non-Critical
lnc Lower Non-Critical
lcr Lower Critical
lnr Lower Non-Recoverable
- session
-
-
- info <active | all | id 0xnnnnnnnn | handle 0xnn>
-
Get information about the specified session(s). You may identify
sessions by their id, by their handle number, by their active status,
or by using the keyword `all' to specify all sessions.
- sol
-
-
- info [<channel number>]
-
Retrieve information about the Serial-Over-LAN configuration on
the specified channel. If no channel is given, it will display
SOL configuration data for the currently used channel.
- set <parameter> <value> [channel]
-
Configure parameters for Serial Over Lan. If no channel is given,
it will display SOL configuration data for the currently used
channel. Configuration parameter updates are automatically guarded
with the updates to the set-in-progress parameter.
-
- Valid parameters and values are:
-
- set-in-progress
-
set-complete set-in-progress commit-write
- enabled
-
true false
- force-encryption
-
true false
- force-authentication
-
true false
- privilege-level
-
user operator admin oem
- character-accumulate-level
-
Decimal number given in 5 milliseconds increments
- character-send-threshold
-
Decimal number
- retry-count
-
Decimal number. 0 indicates no retries after packet is transmitted.
- retry-interval
-
Decimal number in 10 millisend increments. 0 indicates
that retries should be sent back to back.
- non-volatile-bit-rate
-
serial, 19.2, 38.4, 57.6, 115.2. Setting this value to
serial indicates that the BMC should use the setting used
by the IPMI over serial channel.
- volatile-bit-rate
-
serial, 19.2, 38.4, 57.6, 115.2. Setting this value to
serial indiates that the BMC should use the setting used
by the IPMI over serial channel.
- activate
-
Causes ipmitool to enter Serial Over LAN
mode, and is only available when using the lanplus
interface. An RMCP+ connection is made to the BMC,
the terminal is set to raw mode, and user input is
sent to the serial console on the remote server.
On exit,the the SOL payload mode is deactivated and
the terminal is reset to its original settings.
-
Special escape sequences are provided to control the SOL session:
-
- ~. Terminate connection
-
- ~^Z Suspend ipmitool
-
- ~B Send break
-
- ~~ Send the escape character by typing it twice
-
- ~? Print the supported escape sequences
-
- deactivate
-
Deactivates Serial Over LAN mode on the BMC.
Exiting Serial Over LAN mode should automatically cause
this command to be sent to the BMC, but in the case of an
unintentional exit from SOL mode, this command may be
necessary to reset the state of the BMC.
- user
-
-
- summary
-
Displays a summary of userid information, including maximum number of userids,
the number of enabled users, and the number of fixed names defined.
- list
-
Displays a list of user information for all defined userids.
- set
-
-
- name <userid> <username>
-
Sets the username associated with the given userid.
- password <userid> [<password>]
-
Sets the password for the given userid. If no password is given,
the password is cleared (set to the NULL password). Be careful when
removing passwords from administrator-level accounts.
- disable <userid>
-
Disables access to the BMC by the given userid.
- enable <userid>
-
Enables access to the BMC by the given userid.
- test <userid> <16|20> [<password>]
-
Determine whether a password has been stored as 16 or 20 bytes.
NOTE: To determine on which channel the LAN interface
is located, issue the `channel info channel' command.
OPEN INTERFACE
The ipmitool open interface utilizes the OpenIPMI
kernel device driver. This driver is present in all modern
2.4 and all 2.6 kernels and it should be present in recent
Linux distribution kernels. There are also IPMI driver
kernel patches for different kernel versions available from
the OpenIPMI homepage.
The required kernel modules is different for 2.4 and 2.6
kernels. The following kernel modules must be loaded on
a 2.4-based kernel in order for ipmitool to work:
- ipmi_msghandler
-
Incoming and outgoing message handler for IPMI interfaces.
- ipmi_kcs_drv
-
An IPMI Keyboard Controler Style (KCS) interface driver for the message handler.
- ipmi_devintf
-
Linux character device interface for the message handler.
The following kernel modules must be loaded on
a 2.6-based kernel in order for ipmitool to work:
- ipmi_msghandler
-
Incoming and outgoing message handler for IPMI interfaces.
- ipmi_si
-
An IPMI system interface driver for the message handler.
This module supports various IPMI system interfaces such
as KCS, BT, SMIC, and even SMBus in 2.6 kernels.
- ipmi_devintf
-
Linux character device interface for the message handler.
Once the required modules are loaded there will be a dynamic
character device entry that must exist at /dev/ipmi0.
For systems that use devfs or udev this will appear at
/dev/ipmi/0.
To create the device node first determine what dynamic major
number it was assigned by the kernel by looking in
/proc/devices and checking for the ipmidev
entry. Usually if this is the first dynamic device it will
be major number 254 and the minor number for the first
system interface is 0 so you would create the device
entry with:
mknod /dev/ipmi0 c 254 0
ipmitool includes some sample initialization scripts that
can perform this task automatically at start-up.
In order to have ipmitool use the OpenIPMI device interface
you can specifiy it on the command line:
ipmitool -I open <command>
BMC INTERFACE
The ipmitool bmc interface utilizes the bmc device driver as
provided by Solaris 10 and higher. In order to force ipmitool to make
use of this interface you can specify it on the command line:
<pp>
ipmitool -I bmc <command>
The following files are associated with the bmc driver:
- /platform/i86pc/kernel/drv/bmc
-
32-bit ELF kernel module for the bmc driver.
- /platform/i86pc/kernel/drv/amd64/bmc
-
64-bit ELF kernel module for the bmc driver.
- /dev/bmc
-
Character device node used to communicate with the bmc driver.
LIPMI INTERFACE
The ipmitool lipmi interface uses the Solaris 9 IPMI kernel device driver.
It has been superceeded by the bmc interface on Solaris 10. You can tell
ipmitool to use this interface by specifying it on the command line.
ipmitool -I lipmi <expression>
LAN INTERFACE
The ipmitool lan interface communicates with the BMC
over an Ethernet LAN connection using UDP under IPv4. UDP
datagrams are formatted to contain IPMI request/response
messages with a IPMI session headers and RMCP headers.
IPMI-over-LAN uses version 1 of the Remote Management Control
Protocol (RMCP) to support pre-OS and OS-absent management.
RMCP is a request-response protocol delivered using UDP
datagrams to port 623.
The LAN interface is an authenticatiod multi-session connection;
messages delivered to the BMC can (and should) be authenticated
with a challenge/response protocol with either straight
password/key or MD5 message-digest algorithm. ipmitool will
attempt to connect with administrator privilege level as this
is required to perform chassis power functions.
You can tell ipmitool to use the lan interface with the
-I lan option:
ipmitool -I lan -H <hostname>
[-U <username>] [-P <password>] <command>
A hostname must be given on the command line in order to use the
lan interface with ipmitool. The password field is optional;
if you do not provide a password on the command line, ipmitool
will attempt to connect without authentication. If you specify a
password it will use MD5 authentication if supported by the BMC
and straight password/key otherwise, unless overridden with a
command line option.
LANPLUS INTERFACE
Like the lan interface, the lanplus interface
communicates with the BMC over an Ethernet LAN connection using
UDP under IPv4. The difference is that the lanplus
interface uses the RMCP+ protocol as described in the IMPI v2.0
specification. RMCP+ allows for improved authentication and data
integrity checks, as well as encryption and the ability to carry
multiple types of payloads. Generic Serial Over LAN support
requires RMCP+, so the ipmitool sol activate command
requires the use of the lanplus interface.
RMCP+ session establishment uses a symmetric challenge-response
protocol called RAKP (Remote Authenticated Key-Exchange Protocol)
which allows the negotiation of many options. ipmitool does not
yet allow the user to specify the value of every option, defaulting
to the most obvious settings marked as required in the v2.0
specification. Authentication and integrity HMACS are produced with
SHA1, and encryption is performed with AES-CBC-128. Role-level logins
are not yet supported.
ipmitool must be linked with the OpenSSL library in order to
perform the encryption functions and support the lanplus
interface. If the required packages are not found it will not be
compiled in and supported.
You can tell ipmitool to use the lanplus interface with the
-I lanplus option:
ipmitool -I lanplus
-H <hostname>
[-U <username>]
[-P <password>]
<command>
A hostname must be given on the command line in order to use the
lan interface with ipmitool. With the exception of the -A and
-C options the rest of the command line options are identical to
those available for the lan interface.
The -C option allows you specify the authentication, integrity,
and encryption algorithms to use for for lanplus session based
on the cipher suite ID found in the IPMIv2.0 specification in table
22-19. The default cipher suite is 3 which specifies
RAKP-HMAC-SHA1 authentication, HMAC-SHA1-96 integrity, and AES-CBC-128
encryption algorightms.
EXAMPLES
- Example 1: Listing remote sensors
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
Baseboard 1.25V | 1.24 Volts | ok
Baseboard 2.5V | 2.49 Volts | ok
Baseboard 3.3V | 3.32 Volts | ok
- Example 2: Displaying status of a remote sensor
-
> ipmitool -I lan -H 1.2.3.4 -f passfile sensor get "Baseboard 1.25V"
Locating sensor record...
Sensor ID : Baseboard 1.25V (0x10)
Sensor Type (Analog) : Voltage
Sensor Reading : 1.245 (+/- 0.039) Volts
Status : ok
Lower Non-Recoverable : na
Lower Critical : 1.078
Lower Non-Critical : 1.107
Upper Non-Critical : 1.382
Upper Critical : 1.431
Upper Non-Recoverable : na
- Example 3: Displaying the power status of a remote chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power status
Chassis Power is on
- Example 4: Controlling the power on a remote chassis
-
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
Chassis Power Control: Up/On
AUTHOR
Duncan Laurie <duncan@iceblink.org>
SEE ALSO
- IPMItool Homepage
-
http://ipmitool.sourceforge.net
- Intelligent Platform Management Interface Specification
-
http://www.intel.com/design/servers/ipmi
- OpenIPMI Homepage
-
http://openipmi.sourceforge.net
Index
- NAME
-
- SYNOPSIS
-
- DESCRIPTION
-
- OPTIONS
-
- SECURITY
-
- COMMANDS
-
- OPEN INTERFACE
-
- BMC INTERFACE
-
- LIPMI INTERFACE
-
- LAN INTERFACE
-
- LANPLUS INTERFACE
-
- EXAMPLES
-
- AUTHOR
-
- SEE ALSO
-
|
|
Check this page for dead links, sloppy HTML, or a bad style sheet; or strip
it for printing.
|
|
Any opinions, findings, and conclusions or recommendations
expressed in this material are those of the author(s) and do not necessarily
reflect the views of the National Science Foundation.
|
|