Review Committee Meeting Monday 1 October 2007 08:00 Pacific / 11:00 Eastern

Minutes: Monday 1 October 2007 08:00 Pacific / 11:00 Eastern

Agenda and Contact Info

Agenda

  1. GRB070201 Search
    • Summary [ HTML ]
    • Latest Version of Paper [ PDF ]
    • Isabel's V03 Results [ HTML ]
  2. Review of BurstMDC Simulation
    • Summary of S5 BurstMDC Simulation [ HTML ]
    • Technical Documentation [ HTML ]
    • Source Code [ HTML ]
  3. A.O.B.

Contact Info

InterCall telecon service:
   Phone: 1-866-380-5536, participant code: 435 672 9587 #
   International callers ++1-816-249-4731 with same code
   International access numbers (~10 cents/min surcharge for LIGO Lab):
      Paris 017 080 7156 ;
      Lyon 042 603 0036 ;
      Germany toll-free 0800 182 1591 ;
      Berlin 030 726 167 371 ;
      Rome 00645 217 080 ;
      UK toll-free 0808 234 7914 ;
      London 0203 107 0293
   Handy participant command:  Press *6 ["*M"] to mute, #6 to unmute

Minutes

  1. GRB070201 Search
    • V03 inspiral results. Would like a histogram of difference between end time and tccmax.
    • Jolien will write down effective distance calculation with predicted Deff at 90% efficiency.
    • Systematic uncertainties: Need to account for abs(R), arg(R), D_M31, MonteCarlo error.
    • Proposal 10% in abs(R), 10 deg in arg(R), 10% in D_M31, and binomial distribution for MC.
    • Issue of calibration: gamma used in injection was from Official V03 Calibration, which was unity for the epoch of GRB070201. Isabel uses a table of gamma values that were subsequently computed for GRB070201. The values are about 1.03. This means:
      qinj = h / RV03
      while if we had used the true calibration we would have
      qtrue = h / Rtrue
      so
      qinj = (Rtrue / RV03) qtrue
      now the response function is
      R = (1 + gamma G)/(gamma C) ~ 1/(gamma C)
      take gammaV03 = 1, gammatrue = 1.03,
      qinj ~ (1/1.03) htrue
      so it seems that the injections are about 3% smaller than anticipated. This (over)covers uncertainty in calibration factors.